Description
The Yato air source heat pump cleaning cover is a protective bag fitted around the indoor unit that collects the wash water, detergent and loosened dirt while the wall unit of an air source heat pump or air conditioner is being washed. The enclosed design stops water from splashing onto walls, the floor and furniture.
The cover consists of left and right support plates, a waterproof front curtain, a rear shield and a 2.8 m long drain hose. The support plates keep the cover in shape at the sides of the unit. The rear shield protects the wall behind the unit.
Dirty water runs to the bottom of the cover and from there along the drain hose into a container on the floor. This way the indoor unit’s fins and fan can be washed with water and detergent without the room getting wet.
The Yato air source heat pump cleaning cover is available in two sizes according to the width of the indoor unit. The cover is quick to assemble and dismantle, so it suits the cleaning and disinfection of wall units in residential buildings, offices and commercial premises.
Uses and suitability:
The cleaning cover is intended for service washing of wall-mounted indoor units.
- Washing a heat pump indoor unit: Washing the fins and fan with water and detergent indoors. The cover collects the running water and dirt, which are led through the hose into a container.
- Air conditioner servicing: Periodic cleaning and disinfection of split system wall units in homes, offices and commercial premises.
- Public premises: Servicing in premises where floors, walls and furniture have to be kept dry and clean during the work.
Package contents:
- Support plates: left and right side supports.
- Front curtain: waterproof.
- Rear shield: to protect the wall.
- Drain hose: 2.8 m.
Features:
- Enclosed design: The cover surrounds the indoor unit so that wash water does not splash onto the surroundings.
- Waterproof front curtain: The curtain keeps water and detergent inside the cover.
- Support plates: The left and right support plates keep the cover in shape at the sides of the unit.
- Rear shield: Protects the wall behind the indoor unit from getting wet.
- Drain hose 2.8 m: Leads the dirty water from the bottom of the cover into a container on the floor.
- Quick installation and removal: The cover is fitted and removed during the same service visit.
- Two sizes: The size is chosen according to the width of the indoor unit.
Technical specifications:
- Unit type: wall-mounted indoor unit (air source heat pump, air conditioner).
- Indoor unit width: model-specific, two sizes.
- Drain hose length: 2.8 m.
- Front curtain: waterproof.
- Design: enclosed cover, left and right support plates, rear shield.
- Purpose: protecting the surroundings while the indoor unit is washed and disinfected.
User instructions for the Yato air source heat pump cleaning cover:
The cleaning cover is fitted around the indoor unit before washing. The power to the unit is switched off for the whole job.
- Switch off the power to the indoor unit at the plug or the fuse.
- Open the front panel of the indoor unit and remove the air filters according to the unit’s user manual.
- Place the support plates on the left and right sides of the indoor unit. Fit the rear shield between the unit and the wall.
- Pull the elastic edge of the cover around the indoor unit so that the front curtain covers the front of the unit and the bottom of the cover sits under the unit.
- Connect the drain hose to the drain connection of the cover. Lead the end of the hose into a bucket on the floor so that the hose slopes down towards the container all the way.
- Wash the fins and fan according to the detergent manufacturer’s instructions. Wear safety glasses and protective gloves.
- Let the water drain through the hose into the container. Remove the cover carefully so that the water left at the bottom does not spill.
- Rinse and dry the cover before storage. Switch the power back on only when the indoor unit has dried.
Warnings:
- Electrical safety: Switch off the power to the unit before washing. Water must not get into the unit’s electrical parts, control board or connections.
- Safety glasses and protective gloves: Detergents can irritate the eyes and skin.
- Working at height: Use a stable ladder or work platform. Empty the cover before removing it, as the water adds to its weight.
- Overflow: Check that the drain hose is not kinked and that there is room in the container.
- Indoor unit fixing: Do not lean on the indoor unit or load its brackets when fitting the cover.
- Risk of suffocation: Keep plastic parts and the hose out of the reach of children.
Frequently asked questions (FAQ):
What is the Yato air source heat pump cleaning cover used for?
The Yato cleaning cover is fitted around the indoor unit of a wall-mounted air source heat pump or air conditioner for washing. It collects the water, detergent and dirt, which are led through the 2.8 m drain hose into a container on the floor.
What size of indoor unit does the Yato cleaning cover fit?
The Yato air source heat pump cleaning cover comes in two sizes, chosen according to the width of the indoor unit. Measure the width of the unit and choose the model whose width range covers the unit.
What does the Yato cleaning cover package contain?
The Yato air source heat pump cleaning cover package contains the left and right support plates, a waterproof front curtain, a rear shield and a 2.8 m long drain hose.
Does the heat pump power have to be switched off before washing?
Yes. The power to the indoor unit is switched off before the Yato cleaning cover is fitted. The unit is switched back on only when the indoor unit has dried.
Can the Yato cleaning cover be used several times?
Yes. The Yato air source heat pump cleaning cover is rinsed and dried after use and then assembled again for the next wash.
Recycling instructions:
At the end of its life, sort the Yato air source heat pump cleaning cover by the materials of its parts according to local waste management guidelines. The clean plastic drain hose goes to plastic recycling. The printed cardboard packaging goes to cardboard recycling.